excepting any waivers granted via ordinance 2024-33.
Low maintenance materials are required for the fencing, wood is not permitted.
Brick shall be clay, baked and individually laid.
Stone shall be individually laid.
All floodplain policies shall be adhered to.
Each amenity area shall be completed upon completion of its respective phase.
Provide farm style fencing along the Residential collector/York Road property line to
enhance streetscape. Fencing shall be of a low maintenance material.
For all wet ponds, please include lighted fountains.
Provide how future homeowners will be notified of the firing range located to the
immediate south of the property.
2.
3.
4.
5.
6.
7.
8.
9.
10. Correct the master building setbacks for lot 81.
11. Provide a landscape plan. Submittal of construction documents to Public Works is
not possible until the landscape plans are approved.
Public Works:
1. Previously approved PUD/PMDP conditions apply.
2. Preliminary drainage report under review. A comprehensive review of the drainage
report will take place at construction plan review.
3. All storm pipe in the ROW shall have a min. diameter of 18”.
4. Stormwater: Water Quality - TN Rule 400-10-.04 applies
5. Stormwater: Water Quality - 100-year flood detention required.
6. Landscaping plans shall be approved prior to the approval of construction plan
review.
7. A letter of approval from West Wilson Utility District will be needed prior to
construction plan approval is issued.
8. The development proposes directing its wastewater flow to the Paradise Dr. pump
station. The developer shall be responsible for all improvements/upgrades to the
existing Paradise Dr. pump station to serve this development.
9. Per the Land Development Code, existing steep slopes are not permitted within
building envelopes.
10. Add note: All PUDEs outside of the ROW are not the maintenance responsibility of
the City of Mt. Juliet.
11. In the event karst features are encountered during grading, a licensed geotechnical
engineer shall document the feature, and the feature shall be located by a licensed
surveyor. If the feature is to be remediated, the geotechnical engineer shall provide a
remediation plan to the City for approval. Efforts will be made to minimize any
remediated features within building envelopes.
12. The on-street parking shall be parallel spaces.
13. The crosswalks at the roundabout shall be immediately behind the splitter island.
14. The extent of sidewalk required on York Road is to be negotiated between the
development and Public Works/Engineering. At a minimum, sidewalk shall be
provided on all residential frontages and connect to the trails. Pedestrian crossings
shall be provided where sidewalks end.
15. If the FMDP is approved by the Planning Commission, submit a digital copy of the
plans and drainage report to Engineering for construction plan approval.
WWUD:
1. The Water lines shown are not WWUD’s design.