22. Provide trash receptacles per code.
23. Fire pits shall be set in a brick or stone base.
24. Dumpster enclosure and trash compactors shall be faced with masonry and meet the
requirements of 6-103.7, regulations for dumpster enclosures.
25. 2,000sf of clubhouse area, up to 200 units, is required, plus 10sf per each additional
dwelling in multifamily areas per multi-family regulations.
26. Provide commercial and/or mixed uses along the entire Golden Bear Gateway
frontage in lieu of the townhomes/strictly residential as this is a major commercial
corridor in the City.
27.
Detention ponds, easements, etc. shall not be counted towards improved
open space requirements.
28. Provide decorative streetlighting at the entrances and throughout the PUD per
recently approved ordinance 2025-24.
29. Parking lot lighting shall be decorative fixtures mounted to black poles. Poles shall
be placed in landscaped areas or yards not in the parking lot.
30. Paint wall mounted utility equipment and meters to match the building façade it is
attached to.
31. Landscape buffers shall be located in open space and not on individual lots. The
HOA or management company shall be responsible for the maintenance of all buffers.
32. Mail kiosks shall be covered, lighted and include designated parking.
33. Signage to be reviewed via a separate application to the Planning Department.
34. The full complement of required parking shall be provided.
35. The Planning Commission positively recommended a waiver to 6-103.3 allowing for
a max height of 55’ on the proposed buildings.
36. The Planning Commission positively recommended a waiver to 4-114.1 and 5-104.4 -
allowing for 70% MASONRY AND 30% SECONDARY Hardie and board and batten for
multi family.
37. The applicant offered to reduce the town homes in phase 2A in order to add 20k-25k
sqft of commercial space. The Planning Commission positively recommended that it be
done.
38. The Planning Commission did not make a recommendation on the sale of the City
property.
39. The Planning Commission supported a waiver to 5-104a.4 - Allowing the Omit
perimeter fence around multifamily.
40. The Planning Commission did not support a waiver to 5-104.4 - allowing for less
than 22’ long driveways for alley loaded and front-loaded townhomes.
41. The Planning Commission supported a waiver to 5-104.4 - allowing for the
omittance of the masonry column between single family two car garages front facing if
a decorative door is used.
42. The Planning Commission did not support a waiver to 5-104.4 - Front facing, single
family garage doors to be 50% of the front façade if a decorative garage door is used.
43. The Planning Commission supported at waiver to 5-104.4 - allowing for
single-family, front-loaded garages to be flush with the front façade.
44. The Planning Commission supported a waiver to 5-104.4 allowing for single family
lots as small as 8,000 sqft.
45. The Planning Commission supported a waiver to 6.102.1 allowing for a grocery store
to be as small as 10,000 sqft.
46. The Planning Commission did not support a waiver to 6-103.7.3 to omit sidewalks in
areas that require environmental impact.